Recovering electric vehicles (EVs

ARC Flash Visors & Fire-Retardant Clothing

£0.00 In Stock

Description

ARC Flash Visors & Fire-Retardant Clothing
Product Description:

ARC Flash Visors & Fire-Retardant (FR) Clothing provide life-saving thermal and electrical arc flash protection for technicians and emergency recovery teams working around high-voltage systems (up to 800V DC). Designed specifically to mitigate the hazards of violent arc faults, high-heat release, and molten metal splatter during high-voltage battery disconnects or post-collision handling, this personal protective equipment (PPE) ensures full-body thermal resistance and optical safety without compromising operator dexterity or field visibility.

_________________________________
Key Technical Specifications:

Arc Thermal Performance Value (ATPV): Rated at minimum 8 cal/cm² to 12 cal/cm² (PPE Category 2), providing robust protection against high-energy thermal exposures.

Standards Compliance: Fully compliant with NFPA 70E, IEC 61482-2 (Arc Flash Clothing), and EN 166 / GS-ET-29 (Arc-Tested Face Shields).

Optical Visor Quality: Anti-fog, anti-scratch polycarbonate face shield with high Light Transmittance (VLT > 60%) to ensure accurate color recognition of high-voltage wiring (orange, red, black).

Inherently Flame-Resistant Fabric: Manufactured from aramid/modacrylic blends that will not melt, drip, or ignite when exposed to direct flames or electrical arcing.

Ergonomic & Breathable Fit: Lightweight, moisture-wicking fabric construction with adjustable visor ratchet headgear for prolonged comfort during complex recovery operations.

Primary Applications in EV Handling:

High-Voltage Battery Disconnection: Worn when pulling service disconnect plugs, cutting emergency lines, or manual battery isolation on compromised EVs.

Post-Accident Scene Management: Protects first responders and tow operators from unexpected electrical arcing or rapid thermal energy release on crashed vehicles.

Live System Diagnostics & Testing: Used during insulation resistance checks or live voltage testing around exposed 400V/800V busbars and inverters.

Fire & Off-Gassing Protection: Provides supplementary flame protection during early-stage battery cell off-gassing or thermal runaway containment.

Before you order

Payments, postage & returns

Delivery cost, estimated timing and returns information are shown before purchase.

Send inquiry→ Chat now→ View full policy →

Delivery

Standard UK delivery FREE for orders over £300 excl (vat)
Next Working Day Dispatch Monday to Friday Order by 1.00pm
Estimated dispatch
Tue, 13 Oct 2026
Estimated delivery
Thu, 15 Oct 2026 – Fri, 16 Oct 2026
Dispatch basis
Normally within 1 working day
Delivery basis
2–3 working days after dispatch
Mainland UK
Order Iterm below 27kg day

Dates are estimates and can be affected by weekends, bank holidays and courier disruption.

Minimum-order calculation

Product
£0.00 each
Minimum quantity
1
Goods total
£0.00
Standard delivery
FREE
Estimated minimum-order total
£0.00

The displayed minimum-order total is a worked example. The final checkout total is calculated from the quantity selected and the applicable checkout charges/taxes.

Payment

Payment options are shown during checkout.

Card PayPal Bank transfer Direct Debit

Payment is processed through the available checkout/payment route; raw card security data is not stored by this page.

Cancellation & returns

For most consumer distance sales, the statutory cancellation period is 14 days from the day the goods come into your physical possession.

Our additional commercial return period is 30 days, subject to the published return terms.

Return postage under the current configured store policy: paid by the seller.

Read the full cancellation and returns terms →
Information before purchase

Applicable delivery charges and delivery arrangements should be clear before the customer is bound by the order. The checkout must show the final total and the payment obligation before submission.

Product Specifications

  • Arc Thermal Performance Value (ATPV) Rated at minimum 8 cal/cm² to 12 cal/cm² (PPE Category 2), providing robust protection against high-energy thermal exposures.
  • Standards Compliance Fully compliant with NFPA 70E, IEC 61482-2 (Arc Flash Clothing), and EN 166 / GS-ET-29 (Arc-Tested Face Shields).
  • Optical Visor Quality Anti-fog, anti-scratch polycarbonate face shield with high Light Transmittance (VLT > 60%) to ensure accurate color recognition of high-voltage wiring (orange, red, black).
  • Inherently Flame Resistant Fabric Manufactured from aramid/modacrylic blends that will not melt, drip, or ignite when exposed to direct flames or electrical arcing.
  • Ergonomic & Breathable Fit Lightweight, moisture-wicking fabric construction with adjustable visor ratchet headgear for prolonged comfort during complex recovery operations.
  • Primary Applications In EV Handling ....
  • High Voltage Battery Disconnection Worn when pulling service disconnect plugs, cutting emergency lines, or manual battery isolation on compromised EVs.
  • Post Accident Scene Management Protects first responders and tow operators from unexpected electrical arcing or rapid thermal energy release on crashed vehicles.
  • Live System Diagnostics & Testing Used during insulation resistance checks or live voltage testing around exposed 400V/800V busbars and inverters.
  • Fire & Off Gassing Protection Provides supplementary flame protection during early-stage battery cell off-gassing or thermal runaway containment.